Adaptación de lente de contacto blando en miopía magna en paciente masculino de 25 años.
dc.contributor.advisor | Martínez Mora, Stalin Fabián | |
dc.contributor.author | Quinatoa Barriga, Jusselly Aylleen | |
dc.date.accessioned | 2023-06-13T13:11:38Z | |
dc.date.available | 2023-06-13T13:11:38Z | |
dc.date.issued | 2023 | |
dc.identifier.uri | http://dspace.utb.edu.ec/handle/49000/14459 | |
dc.description | The present study shows the case of a patient with high myopia of -8.00 diopters to whom a soft contact lens with spherical dioptric power was adapted, in order to improve its visual and optical quality, for this it is necessary to determine the adaptation parameters of the contact, such as the final dioptric power of the lens considering the distance to the vertex present in aerial lenses, the diameter and the base curve of the lens. Pre-adaptation tests were performed such as visual acuity, objective and subjective refraction, contrast sensitivity, biomicroscopy, direct ophthalmoscopy, Schirmer's test and tear breakup time (BUT), which allowed knowing the refractive status of the patient, ocular physiology, lacrimal system in terms of quantity and quality. The results showed that the patient is apt to be a contact lens user due to presenting an optimal tear film and keratometric values considered normal (43 D), for which the hydrogel contact lens will be prolonged with a refractive power of -7.25 diopters, diameter 14.0mm and base curve of 8.6. At the end of the adaptation and checking the visual acuity in relation to the frame lens improved from 20/630 to 20/32 and contrast sensitivity from 1.20 to 1.50, greater comfort was acquired when carrying out work activities, sharpness in peripheral vision and esthetic. | es_ES |
dc.description | The present study shows the case of a patient with high myopia of -8.00 diopters to whom a soft contact lens with spherical dioptric power was adapted, in order to improve its visual and optical quality, for this it is necessary to determine the adaptation parameters of the contact, such as the final dioptric power of the lens considering the distance to the vertex present in aerial lenses, the diameter and the base curve of the lens. Pre-adaptation tests were performed such as visual acuity, objective and subjective refraction, contrast sensitivity, biomicroscopy, direct ophthalmoscopy, Schirmer's test and tear breakup time (BUT), which allowed knowing the refractive status of the patient, ocular physiology, lacrimal system in terms of quantity and quality. The results showed that the patient is apt to be a contact lens user due to presenting an optimal tear film and keratometric values considered normal (43 D), for which the hydrogel contact lens will be prolonged with a refractive power of -7.25 diopters, diameter 14.0mm and base curve of 8.6. At the end of the adaptation and checking the visual acuity in relation to the frame lens improved from 20/630 to 20/32 and contrast sensitivity from 1.20 to 1.50, greater comfort was acquired when carrying out work activities, sharpness in peripheral vision and esthetic. | es_ES |
dc.description.abstract | El presente estudio muestra el caso de paciente con miopía magna de -8.00 dioptrías al que se adaptó lente de contacto blando con poder dióptrico esférico, a fin de mejorar su calidad visual y óptica, para ello fue necesario determinar los parámetros de adaptación de lente de contacto, como el poder dióptrico final de la lente, considerando la distancia al vértice presente en los lentes aéreos, el diámetro y curva base del lente. Se realizaron las pruebas pre adaptación como agudeza visual, refracción objetiva y subjetiva, sensibilidad al contraste, biomicroscopia, oftalmoscopia directa, test de Schirmer y tiempo de rotura lagrimal (BUT), que permitieron conocer el estado refractivo del paciente, la fisiología ocular y la integridad lagrimal en cuanto a cantidad y calidad. Los resultados obtenidos demostraron que el paciente es apto a ser usuario de lente de contacto por presentar una película lagrimal optima y valores queratométricos considerados normales (43 D) por lo que se determinó lente de contacto de hidrogel con poder refractivo de -7.25 dioptrías, diámetro 14.0mm y curva base de 8.6. Al finalizar la adaptación y comprobar la agudeza visual en relación con el lente de armazón mejoró de 20/630 a 20/32 y la sensibilidad al contraste de 1.20 a 1.50, se adquirió mayor comodidad al realizar sus actividades laborales, nitidez en visión periférica y estética. | es_ES |
dc.format.extent | 42 p. | es_ES |
dc.language.iso | es | es_ES |
dc.publisher | Babahoyo: UTB-FCS, 2023 | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | Lentes de contacto | es_ES |
dc.subject | Miopía magna | es_ES |
dc.subject | Agudeza visual | es_ES |
dc.subject | Test de Schirmer | es_ES |
dc.subject | BUT | es_ES |
dc.title | Adaptación de lente de contacto blando en miopía magna en paciente masculino de 25 años. | es_ES |